Causes of ultrafiltration membrane fouling and its harm to the system
Time:2022-04-12

Membrane fouling is the biggest problem during the operation of ultrafiltration device, and it is also one of the most common problems of ultrafiltration device. The pollution is mainly manifested in the reduction of water yield and the deterioration of water quality. At the same time, with the increase of water inlet pressure, the transmembrane pressure difference increases, and there is a certain phenomenon of wire breakage. The greater the transmembrane pressure difference, the more serious the wire breakage phenomenon will be.

Causes of fouling in ultrafiltration system:

(1) The inlet water temperature of ultrafiltration is too low, resulting in the increase of operation resistance;

(2) Ultrafiltration membrane fouling is caused by raw water pollution, too many bacteria and algae, that is, the SDI of influent is too high, resulting in ultrafiltration fouling;

(3) The influent flow of ultrafiltration increases, which exceeds the water production capacity of the filter membrane;

(4) The inlet pressure is too high. In order to increase the water production, artificially increase the inlet pressure of ultrafiltration.

When ultrafiltration is polluted, it will have a great impact on RO system and increase pollution blockage, mainly in the following aspects:

(1) The water quality deteriorates, the SDI value becomes higher or exceeds the standard, and the color of the SDI value test diaphragm becomes darker;

(2) The reverse osmosis membrane is polluted and blocked, resulting in the rapid decline of water production rate of the reverse osmosis system;

(3) When the UF is seriously polluted, a layer of "sponge" will be generated in the UF. During chemical cleaning, the residual NaOH or sodium hypochlorite can not be washed in time, which will be released slowly, which will bring serious harm to the subsequent RO system.

Therefore, in ultrafiltration operation, it is generally designed with forward flushing, backflushing and conventional on-line automatic pH adjustment immersion cleaning. Generally, it is backwashed once from 20min to 1H; Conduct a low pH or high pH cleaning for more than 8h. When adjusting the pH, generally soak for 10min, and then conduct physical flushing. When soaking with alkaline solution, a certain amount of NaClO is often added to enhance the cleaning effect.

The filtration mode of membrane is divided into dead end and cross flow. Dead end filtration, also known as full flow filtration, means that the flow direction of the liquid is perpendicular to the membrane surface. After the filtered liquid passes through the membrane, all the intercepts are deposited on the membrane surface. This filtration mode has a high probability of blockage and is generally suitable for water quality with low turbidity and low suspended solids content. Cross flow filtration can realize the continuous operation of ultrafiltration device and meet the scale requirements of large flow. In cross flow filtration, the water flow is parallel to the surface of the filter membrane, which can form a large shear force on the surface of the filter membrane, resulting in the membrane pollutants always in a suspended state, reducing the impact of concentration polarization, reducing the deposition of particles and solutes on the membrane surface and reducing membrane pollution. Therefore, the cross flow mode has strong adaptability to the water quality of feed water. In addition, increasing the cross flow velocity can also improve the critical flux.

When the TMP increases to a certain level and cannot be recovered through cross flow and backwashing, chemical cleaning can be used to recover the membrane flux. Through contact with a certain dose of chemicals and under the action of large flow cleaning, the pollutants on the membrane surface and membrane pores can be removed, so as to restore the flux of the membrane.

Most ultrafiltration equipment adopts hollow fiber membrane wire. It is a common phenomenon that a small amount of wire breakage occurs during operation. Wire breakage is generally caused by membrane wire fouling, back impact and other reasons. Tens of thousands of membrane wires are installed in one element, and a small amount of broken wires will not immediately affect the water quality. Therefore, it is not easy to detect during operation. However, once the change of water production quality is found, the accurate position of broken wire should be determined quickly in order to take corresponding measures.

The treatment of broken wire is generally to find out the damaged membrane wire and block it. If the amount of broken wire or blocked membrane wire increases to a certain extent (more than 10%), the whole element needs to be replaced.


Weclome
Sichuan sidaneng Environmental Protection Technology Co., Ltd
MORE
Service Tel:
+86 189-8175-1540
Join Us
无码一区二区三区乱子伦| 亚洲一区二区三区αv电影| 日本熟妇色熟妇在线视频播放| 在线成人精品国产区免费| 大鸡巴爆操嫩穴在线观看| 亚洲国产av动作片不卡| 欧美亚洲综合视频在线观看| 精品少妇嗷嗷叫在线观看| 亚洲中字慕日产2020| 欧美熟妇另类久久久久久久| 精品裸体舞一区二区视频| 99久久综合国产精品二区| 性刺激久久久久久久久游戏| 一本大道东京热aV无码| 国产偷国产偷亚洲高清人| 国产成人亚洲精品青草天美| 亚洲欧美精品一区在线观看| 欧美激情,亚洲A∨综合| 国产一二三区精品亚洲美女| 国产精品久久久久久爽爽爽床戏| 亚洲国产成人va在线网页| 国产丨熟女丨国产熟女一区| 国产福利精品视频在线观看| 久久久久99精品成人片a片试看| 夫妻性生活在线免费视频| 亚洲尤物在线免费观看视频| 日韩精品一区二区三区日韩| 亚洲午夜av久久久精品影院色戒| 亚洲AV无码AV制服丝袜在线| 久久久精品中出内射少妇| 放荡的情欲免费在线观看| 一区二区综合欧美日本中文| 国产污视频在线观看一区| 热99re久久精品香蕉| 日韩精品一区电影在线观看| 大屁股白浆少妇一区二区| 亚日韩精品人妻无码视频| 欧美 亚洲 精品 另类| 久久精品国产| 在线欧美亚洲xxxxx| 成人性视频免费在线观看|