Causes of ultrafiltration membrane fouling and its harm to the system
Time:2022-04-12

Membrane fouling is the biggest problem during the operation of ultrafiltration device, and it is also one of the most common problems of ultrafiltration device. The pollution is mainly manifested in the reduction of water yield and the deterioration of water quality. At the same time, with the increase of water inlet pressure, the transmembrane pressure difference increases, and there is a certain phenomenon of wire breakage. The greater the transmembrane pressure difference, the more serious the wire breakage phenomenon will be.

Causes of fouling in ultrafiltration system:

(1) The inlet water temperature of ultrafiltration is too low, resulting in the increase of operation resistance;

(2) Ultrafiltration membrane fouling is caused by raw water pollution, too many bacteria and algae, that is, the SDI of influent is too high, resulting in ultrafiltration fouling;

(3) The influent flow of ultrafiltration increases, which exceeds the water production capacity of the filter membrane;

(4) The inlet pressure is too high. In order to increase the water production, artificially increase the inlet pressure of ultrafiltration.

When ultrafiltration is polluted, it will have a great impact on RO system and increase pollution blockage, mainly in the following aspects:

(1) The water quality deteriorates, the SDI value becomes higher or exceeds the standard, and the color of the SDI value test diaphragm becomes darker;

(2) The reverse osmosis membrane is polluted and blocked, resulting in the rapid decline of water production rate of the reverse osmosis system;

(3) When the UF is seriously polluted, a layer of "sponge" will be generated in the UF. During chemical cleaning, the residual NaOH or sodium hypochlorite can not be washed in time, which will be released slowly, which will bring serious harm to the subsequent RO system.

Therefore, in ultrafiltration operation, it is generally designed with forward flushing, backflushing and conventional on-line automatic pH adjustment immersion cleaning. Generally, it is backwashed once from 20min to 1H; Conduct a low pH or high pH cleaning for more than 8h. When adjusting the pH, generally soak for 10min, and then conduct physical flushing. When soaking with alkaline solution, a certain amount of NaClO is often added to enhance the cleaning effect.

The filtration mode of membrane is divided into dead end and cross flow. Dead end filtration, also known as full flow filtration, means that the flow direction of the liquid is perpendicular to the membrane surface. After the filtered liquid passes through the membrane, all the intercepts are deposited on the membrane surface. This filtration mode has a high probability of blockage and is generally suitable for water quality with low turbidity and low suspended solids content. Cross flow filtration can realize the continuous operation of ultrafiltration device and meet the scale requirements of large flow. In cross flow filtration, the water flow is parallel to the surface of the filter membrane, which can form a large shear force on the surface of the filter membrane, resulting in the membrane pollutants always in a suspended state, reducing the impact of concentration polarization, reducing the deposition of particles and solutes on the membrane surface and reducing membrane pollution. Therefore, the cross flow mode has strong adaptability to the water quality of feed water. In addition, increasing the cross flow velocity can also improve the critical flux.

When the TMP increases to a certain level and cannot be recovered through cross flow and backwashing, chemical cleaning can be used to recover the membrane flux. Through contact with a certain dose of chemicals and under the action of large flow cleaning, the pollutants on the membrane surface and membrane pores can be removed, so as to restore the flux of the membrane.

Most ultrafiltration equipment adopts hollow fiber membrane wire. It is a common phenomenon that a small amount of wire breakage occurs during operation. Wire breakage is generally caused by membrane wire fouling, back impact and other reasons. Tens of thousands of membrane wires are installed in one element, and a small amount of broken wires will not immediately affect the water quality. Therefore, it is not easy to detect during operation. However, once the change of water production quality is found, the accurate position of broken wire should be determined quickly in order to take corresponding measures.

The treatment of broken wire is generally to find out the damaged membrane wire and block it. If the amount of broken wire or blocked membrane wire increases to a certain extent (more than 10%), the whole element needs to be replaced.


Weclome
Sichuan sidaneng Environmental Protection Technology Co., Ltd
MORE
Service Tel:
+86 189-8175-1540
Join Us
国产麻豆流白浆在线观看| 亚洲精品91一区二区三区| 亚洲精品无码久久千人斩| 亚洲人av成一区二区电影| 青青青青青午夜在线视频| 夜夜草视频免费在线观看| 伊人久久大杳蕉综合大象| 亚洲精品一区二区在线电影| 久久久精品视频免费观看| 成人午夜福利院在线观看| 亚洲中文字幕久久精品品| 高清黑人中出在线小视频| 99久久亚洲国产精品观看| 久久亚洲av午夜福利精品| 亚洲第一区欧美国产综合| 久久久乱码精品亚洲日韩| 色哟哟精品视频一区二区| 日本成人一区二区三区视频| 亚洲 欧美 日韩 精品| 一二三国产亚洲精品电影| av换脸明星一区二区三区| 欧美国产精品成人在线观看| 苍井空HD人妻在线视频| 亚洲av制服丝袜av天堂| 亚洲成aⅤ人片在线观看| 日产精品一区二区| 天天爽夜夜爽夜夜爽精品| 国模精品一区二区三区| 91情侣在线偷精品国产| 亚洲精品另类欧美久久区| 精品国产中文字幕第一页| 无码的免费不卡毛片视频| 上流社会在线观看| 97久久国产亚洲精品超碰热| 国产精品女同久久久久电影院| av午夜男女刺激爽影院| 大香蕉99久久精品视频| 鲁大师影院一区二区三区 | 18禁国精品久久久久久| 一区二区三区日本免费电影| 久久久久亚洲AV佐山爱|